BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Akustik-Blog - ECPv6.15.20//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Akustik-Blog
X-ORIGINAL-URL:https://blog.rwth-aachen.de/akustik
X-WR-CALDESC:Veranstaltungen für Akustik-Blog
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Berlin
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20221030T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20230326T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20231029T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20240331T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20241027T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/Berlin:20231027T110000
DTEND;TZID=Europe/Berlin:20231027T113000
DTSTAMP:20260426T061725
CREATED:20231023T121221Z
LAST-MODIFIED:20231023T121221Z
UID:2799-1698404400-1698406200@blog.rwth-aachen.de
SUMMARY:Braun: Subjektive und objektive Evaluierung der Akustik in Hörsälen der RWTH Aachen University
DESCRIPTION:Das Ziel der Arbeit war\, den Zustand der Raumakustik in Hörsälen der RWTH Aachen University zu erfassen und die Daten zu evaluieren. Dazu wurden Messungen der Raumimpulsantwort in neun Hörsälen auf Basis der DIN EN ISO 3382-1 durchgeführt. Anhand der Impulsantwort wurden raumakustische Gütemaße berechnet\, die für eine gute Sprachverständlichkeit wichtig sind. Zur Evaluierung wurde geprüft\, ob bekannte Grenzwerte für Sprachanwendung auf Hörsäle anwendbar sind und ob diese eingehalten werden. Die Vorgaben der Normen DIN 18041 und DIN EN 60268-16 wurden untersucht und geprüft\, ob diese ausreichend und anwendbar sind. Da Hörsäle die primären Räume der universitären Lehre sind\, wurde ein Fragebogen für Studierende zur Evaluierung der subjektiven Wahrnehmung der raumakustischen Qualität entworfen. Dieser wurde beispielhaft für Hörsaal H03 ausgewertet. Die objektiven\, berechneten Gütemaße wurden für alle Hörsäle verglichen und graphisch in Datenblätern zusammengestellt. Kein Hörsaal erfüllt die Anforderungen an den maximal erlaubten Störschalldruckpegel der bauseitigen Geräusche. Zudem wurden die vorgegebenen Normwerte der Nachhallzeit nur in vier von neun Hörsälen eingehalten. Es konnte gezeigt werden\, dass Nachhallzeiten immer besetzungs- und frequenzabhängig betrachtet werden sollten. Beispiele für gute akustische Planung konnten identifiziert werden\, obwohl die Normwerte nicht in allen Bereichen erfüllt wurden. Grundlegende Anforderungen an die Sprachverständlichkeit wurden in den meisten Hörsälen erfüllt. Trotzdem ist die Sprachverständlichkeit in acht von neun Vorlesungsräumen zu gering\, um gute Bedingungen für Nicht-Mutersprachler:innen zu erfüllen. \n  \nEnglish version: \nTitle: Subjective and objective evaluation of acoustics in lecture halls at RWTH Aachen University \nThe aim of the work was to assess room acoustics in lecture halls of the RWTH Aachen University and to evaluate the data. For this purpose\, measurements of the room impulse response were carried out in nine lecture halls on the basis of DIN EN ISO 3382-1. The impulse response was used to calculate room acoustic quality measures that are important for good speech intelligibility. For evaluation purposes\, it was checked whether known speech application limits are applicable to lecture halls and whether they are met. The specifications of the DIN18041 and DIN EN 60268-16 standards were examined and checked to see if they were sufficient and applicable. Since lecture halls are the primary rooms for university teaching\, a questionnaire was designed for students to evaluate their subjective perception of room acoustic quality. This was evaluated for lecture hall H03 as an example. The objective quality measures were calculated for all lecture halls\, compared and graphically compiled in data sheets. No lecture hall met the requirements for the maximum sound pressure level of on-site noise. In addition\, the specified standard values of the reverberation time were met in only four of nine lecture halls. It could be shown that reverberation times should always be examined as a function of occupancy and frequency. Examples of good acoustic planning could be identified\, although the standard values were not met in all areas. Basic requirements for speech intelligibility were met in most lecture halls. Nevertheless\, speech intelligibility in eight out of nine lecture rooms is too low to meet good conditions for non-native speakers. The talk will be given in German. \nMelden Sie sich hier an um Einladungen zu den Kolloquium-Vorträgen per E-Mail zu erhalten.\nRegister here to receive the invitations to colloquium talks via e-mail. \nZoom-Meeting-ID: 954 4073 3814\nPasswort: 450783
URL:https://blog.rwth-aachen.de/akustik/event/braun-subjektive-und-objektive-evaluierung-der-akustik-in-hoersaelen-der-rwth-aachen-university/
LOCATION:IHTA Seminarraum (60 Persons) and Zoom-Meeting (Hybrid)\, Kopernikusstr. 5\, Aachen\, 52074\, Deutschland
CATEGORIES:Verteidigung Bachelorarbeit
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=Europe/Berlin:20231027T113000
DTEND;TZID=Europe/Berlin:20231027T120000
DTSTAMP:20260426T061725
CREATED:20231023T121320Z
LAST-MODIFIED:20231023T121320Z
UID:2801-1698406200-1698408000@blog.rwth-aachen.de
SUMMARY:Hillert: Industriepraktikum als Projektingenieur in der technischen Gebäudeausrüstung bei WUP Ingenieure
DESCRIPTION:Das studienabschließende Industriepraktikum fand in der Elektro-Abteilung bei WUP Ingenieure statt. Das Unternehmen befasst sich schwerpunktmäßig mit der Planung mehrerer Gewerke der technischen Gebäudeausrüstung. Die Abteilung bestand aus acht Ingenieuren\, in deren Team meine Mitarbeit vom 01.12.2022 bis 12.05.2023 in der Rolle als Fachplaner erfolgte. \nDas Hauptziel innerhalb der Firma WUP war zunächst die Einarbeitung in die wesentlichen technischen Entwicklungs- und Planungsschritte als konkrete Grundlage der betreuten Bauobjekte\, um zunehmend eigenständig Pläne anzufertigen und Berechnungen durchzuführen. \nDie technische Gebäudeausrüstung umfasst allgemein die energetische und stoffliche Versorgung von Gebäuden\, konzentriert sich hier allerdings auf die elektrische Gebäudeversorgung. Dazu gehörte zuvorderst die Stromversorgung der Gebäude mit jeweils individuellen\, durch die Funktion der Bauten bedingten Vorgaben. Hierzu gehörten die Planung von Haupt- und Unterverteilungen sowie die strategische Verlegung der davon ausgehenden Kabeln in Wand\, Decken oder Kabeltrassen. Für die ausfertigenden Nachunternehmer wurden unter Einbezug der Normen und Vorschriften präzise Zeichnungen angefertigt sowie Materialkataloge geführt. Neben der Kabelverlegung erfolgte zudem die Planung von Beleuchtungsanlagen und anderen Endverbrauchern je nach Anforderungen\, Sicherheitsvorgaben und auch Ästhetik. \nEinen weiteren Bereich stellte die Schwachstromtechnik dar. Hier erfolgte die Planung der Datenleitungen als Basis für spätere Netzwerkverbindungen. Ergänzt wurde dieses Arbeitsfeld um Brand- und Einbruchmeldeanlagen sowie die Anforderungen an Türtechnik\, hauptsächlich zur Steuerung von Personen. \nDabei musste stets eine Vernetzung mit den unterschiedlichen Fachplanern der anderen Gewerke stattfinden\, damit Planung und Ausführung reibungslos und DIN-gerecht stattfinden konnten. Das Praktikum brachte daher sehr konkrete Einblicke in die Verzahnung von Theorie und Praxis\, die in fertigen\, nutzbaren Gebäuden wie einem Krankenhaus mündeten. \nMelden Sie sich hier an um Einladungen zu den Kolloquium-Vorträgen per E-Mail zu erhalten.\nRegister here to receive the invitations to colloquium talks via e-mail. \nZoom-Meeting-ID: 954 4073 3814\nPasswort: 450783
URL:https://blog.rwth-aachen.de/akustik/event/hillert-industriepraktikum-als-projektingenieur-in-der-technischen-gebaeudeausruestung-bei-wup-ingenieure/
LOCATION:IHTA Seminarraum (60 Persons) and Zoom-Meeting (Hybrid)\, Kopernikusstr. 5\, Aachen\, 52074\, Deutschland
CATEGORIES:Vortrag Praxissemester
END:VEVENT
END:VCALENDAR